ŸÀÏ/ÄÜÅ©¸®Æ® ºÎÂø·ÂÃøÁ¤±â PosiTest ATA50T, C

* ¹Ì±¹ DeFelsko»çÀÇ 60³â µµ¸·ÃøÁ¤±â ³ëÇÏ¿ì

* µðÁöÅÐ ¹æ½ÄÀÇ ºÎÂø·Â ÃøÁ¤±â
* ±Ý¼Ó, ¸ñÀç, ÄÜÅ©¸®Æ® Ç¥¸éÀÇ ÄÚÆÃ, µµÀåÀÇ ºÎÂø·Â ½ÃÇè
* ¸ñÀç, ÄÜÅ©¸®Æ®À§ ÀÏ¹Ý ÄÚÆÃ(ATA50)
ŸÀϺÎÂø (ATA50T), ÄÜÅ©¸®Æ®À§ ¸ôÅ»(ATA50C) ºÎÂø·Â ½ÃÇè

* »ç¿ëÀÌ °£ÆíÇÏ°í Á¤È®ÇÑ ÃøÁ¤°ª Ç¥½Ã
* ¹«Àü¿ø, ¼ö¾Ð½ÄÆßÇÁ äÅÃÀ¸·Î ÇöÀå¿¡¼­ ÃøÁ¤Æí¸®
* psi, MPa ´ÜÀ§ ¼±Åð¡´É
* Àü¿ë ¼ÒÇÁÆ®¿þ¾î·Î ÃøÁ¤°ª °ü¸® (´Ù¿î·Îµå)

* ASTM D4541, ISO 4624 µî ±× ¹ÛÀÇ ±âÁØÀ» Áؼö
* BS EN 12004-2, ASTM C1583 ±Ô°Ý

¡Ø Prime Distributor 

    DeFelsko ¿Í ´ºÅØ°è±â°¡ Æß¿þ¾î ÇѱÛÈ­ ! 

    [¹Ì±¹»ê] 60³â ¿ª»çÀÇ DeFelsko»ç Á¦Ç°


 

 

 

 

Overview...

* Àü±âÀûÀ¸·Î Á¦¾îµÇ´Â »õ·Î¿î hydraulic pump´Â »ç¿ëÀÚ°¡ ÁöÁ¤ÇÑ ºÎºÐ¿¡

  ºÎµå·´°í Áö¼ÓÀûÀÎ ¾Ð·ÂÀ» ÀÚµ¿ÀûÀ¸·Î °¡¾Ð.
  * ³»ÀåµÈ ÃæÀü¿ë ¹èÅ͸®´Â ÃæÀüÈÄ 200ȸÀÇ Å×½ºÆ®¸¦ ÇÒ ¼ö ÀÖ½À´Ï´Ù.

     ¹èÅ͸®°¡ ¼Ò¸ðµÇ¾úÀ» °æ¿ì¿¡´Â ACÀü¿øÀ» ÀÌ¿ëÇÏ¿© Å×½ºÆ®¸¦ Áö¼Ó.  

     universal AC Adapter°¡ ÇÔ²² Á¦°ø.

  * ¹ÐºÀµÈ ȯ°æ– ¹æ¼ö, ¹æÁø, Ãæ°Ý¹æÁö- meets or exceeds IP65

  * ¹Ì²ô·³ ¹æÁö ¹ßÆÇ, Ãæ°Ý Èí¼ö ±×¸³¾ÈÁ¤ °í¹« Á¦°ø

  * Self-aligning ¾Ë·ç¹Ì´½ µ¹¸®´Â ¸Å²ô ·´°Å³ª ÆòÆòÇÏÁö ¾ÊÀº Ç¥¸é¿¡ Á¤È®ÇÑ ÃøÁ¤.

  * 10, 14, 20 or 50 mm ÀÇ µ¹¸®µé·Î ÀÎÇØ Á¢Âø·ÂÀÇ Àü ºÎºÐ¿¡ °ÉÃļ­ ÃøÁ¤±âÀÇ ¼º´É°ú Á¤È®µµ°¡ ÃÖ´ëÈ­.

  * »ç¿ëÀÚ ÃøÁ¤ ´ÜÀ§ ¼±Åð¡´É : psi (pounds per square inch), MPa (Megapascal),

                                           Nmm2 (Newtons per millimeter square) or  Newton (force)

  * °Ë»çÀå¼ÒÀÇ È¯°æ¿¡ µû¶ó Àåºñ¸¦ °¡·Î ¶Ç´Â ¼¼·Î·Î µð½ºÇ÷¹ÀÌ ÇÏ°í ÀÛµ¿.

  * ¸ðµç ÀåºñÀÇ °¡¾ÐÀåÄ¡´Â NIST±Ô°Ý¿¡ ÁØÇÏ´Â ¡¾1% Á¤¹ÐµµÀÇ load cell·Î ±³Á¤ÇÏ°í ÀÚü ¼ºÀû¼­¸¦ °ø±Þ.

  * ASTM D4541/D7234, ISO4624/16276-1, AS/NZS 1580.408.5 µîÀÇ ±Ô°Ý¿¡ ºÎÇÕÇÑ´Ù.

 

 

    


Self-Alignment Feature

 

The PosiTest Adhesion Tester self-alignment feature compensates for misalignment.

Smart New Features...

 * Å°Æеå ÀÛµ¿ °¡´ÉÇÏ°í Ãæ°Ý¿¡ °­ÇÑ Ä÷¯ ÅÍÄ¡ ½ºÅ©¸°

                 

                          ¸Þ´º ¿É¼Ç°ú »óÈ£ ÀÛ¿ëÇϱâ À§ÇØ ÅÍÄ¡ ½ºÅ©¸°À» »ç¿ëÇÑ´Ù.

                          ¹èÄ¡ Æǵ¶ »çÀ̸¦ À̵¿Çϰųª ¼öÆò Ž»öÇϱâ À§ÇØ ½º¿ÍÀÌÇÁ.

                          ´ë¾ÈÀ¸·Î, Å°Æеå´Â Ž»ö ¹× ¼±ÅÃÀ» À§ÇØ »ç¿ëµÉ ¼öÀÖ´Ù.

 * »ç¿ëÀÚ´Â pull rate, pull limit, hold time Á¶Àý °¡´É

 * ¶³¾îÁü »óÅÂ¿Í Åë°ú/½ÇÆп¡ µû¶ó °á°ú¸¦ ±â·ÏÇÑ´Ù - cohesive, adhesive and glue failures

 * ¹«¼±À¸·Î ¿ì¸®ÀÇ ¹«·á ¾ÛÀ» »ç¿ëÇÏ¿© ½º¸¶Æ® ÀåÄ¡¿¡ ¿¬°á

    ¡Ý Ä«¸Þ¶ó ¶Ç´Â Å°º¸µå¸¦ »ç¿ëÇÏ¿© À̹ÌÁö ¹× ¸Þ¸ð Ãß°¡

    ¡Ý »ç¿ëÀÚ Á¤ÀÇ, Àü¹® PDF º¸°í¼­¸¦ ÀÛ¼º

    ¡Ý °øÀ¯, ¹é¾÷, µ¿±âÈ­ ¹× ÃøÁ¤ µ¥ÀÌÅ͸¦ º¸°í

    ¡Ý ÀÚµ¿ Æä¾î¸µ ºí·çÅõ½º (BLE) ¿¬°á

* ³»ºÎ ¸Þ¸ð¸®´Â ÃÖ´ë Ç®-¿ÀÇÁ ¾Ð·Â, ÃÖ´ë 1,000 ¹èÄ¡¿¡ 100,000°³ ´ç±ä¿¡ ´ëÇÑ Ç®, ½ÃÇè ±â°£°ú

  µ¹¸® »çÀÌÁîÀÇ ¼Óµµ¸¦ ÀúÀåÇÒ ¼ö ÀÖ´Ù.

* ¹«¼± WiFi ±â´É... PosiSoft.net·Î Åë½Å

  ¡Ý  software updates ´Ù¿î·Îµå

  ¡Ý Ç¥ÁØ À¥ ºê¶ó¿ìÀú¸¦ »ç¿ëÇÏ¿© ÀúÀåµÈ ÃøÁ¤ µ¥ÀÌÅ͸¦ ¾×¼¼½º

 

* PosiSoft USB Drive - ÀúÀåµÈ ÃøÁ¤ °ª°ú ±×·¡ÇÁ´Â º¸ÆíÀû ÀÎ PC / ¸Æ À¥ ºê¶ó¿ìÀú ¶Ç´Â ÆÄÀÏ Å½»ö±â¸¦ »ç¿ëÇÏ¿© USB¸¦ ÅëÇØ ¾×¼¼½º.

   º°µµÀÇ ¼ÒÇÁÆ®¿þ¾î°¡ ÇÊ¿äÇÏÁö ¾Ê½À´Ï´Ù.

 * PosiSoft µ¥½ºÅ©Åé ¼ÒÇÁÆ®¿þ¾î, PosiSoft.net ¹× PosiTector ÀÀ¿ë ÇÁ·Î±×·¥°ú ȣȯ

  

Interactive Display Examples...

User adjustable dolly size, pull rate,
pull limit and hold time.

Batch summary provides an at-a-glance review of test results.

View test parameters and reading results. Reading is recorded as pass or fail based on set test parameters. The pass/fail results can be revised.

Notes can be added for each reading.

Include a note for a batch (group) of readings.

Record the nature of failure - cohesive, adhesive and glue failures.

 

* PSI or MPaÀÇ µÎ°¡Áö ¾Ð·Â ´ÜÀ§·Î µð½ºÇ÷¹ÀÌ °¡´É

* 10, 14, 20 or 50 mm ÀÇ µ¹¸®µé·Î ÀÎÇØ Á¢Âø·ÂÀÇ Àü ºÎºÐ¿¡ °ÉÃļ­ ÃøÁ¤±âÀÇ ¼º´É°ú Á¤È®µµ°¡ ÃÖ´ëÈ­ µË´Ï´Ù.

     Dolly Sizeº° ºÎÂø·Â °­µµ

Dolly Size

Adhesion Strength

10mm

10000 psi

70 MPa

14mm

6000 psi

40 MPa

20mm*

3000 psi

20 MPa

50mm**

500 psi

3.5 MPa

* supplied with PosiTest AT
**
requires 50mm kit


 Dollies

 

 

Recording the Nature of the Fracture

pull-offÅ×½ºÆ®°¡ ¿Ï·áµÇ¸é, µ¹¸® ¹× ÄÚÆà ǥ¸éÀ» ºÐ¼®ÇÑ´Ù.

¶ÇÇÑ, pull-off ÈûÀ», ¸¹Àº ±¹°¡¿Í ±¹Á¦ Ç¥ÁØASTM D4541, ISO 4624¿¡¼­´Â ¶³¾îÁü »óÅÂ(fracture)Ư¼º¿¡ ´ëÇÑ

±â·ÏÀ» ÇÊ¿ä·ÎÇÕ´Ï´Ù.

 

Á¢Âø½ÇÆд ÀϹÝÀûÀ¸·Î Á¢ÂøÁ¦°¡ ÀûÀýÇÏ°Ô È¥ÇÕ µÇÁö ¾ÊÀ» ¶§ ¹ß»ýÇϰųª, ÄÚÆà ¸é »óÅ°¡ ºÒ·®ÇÑ °æ¿ì¿¡

¹ß»ýÇÑ´Ù.

PosiTest AT-A ¸ðµ¨Àº °¢°¢ÀÇ pull-offÅ×½ºÆ®¸¦ À§ÇÑ ¶³¾îÁü(fracture) »óŸ¦¹®¼­È­ ÇÒ ¼ö ÀÖ´Â ÀÎÅÍÆäÀ̽º¸¦

Á¦°øÇÕ´Ï´Ù. ¶³¾îÁü(fracture)»óÅ °á°ú´Â Å×½ºÆ® º¸°í¼­¿¡ Æ÷ÇÔÇÒ ¼ö ÀÖ½À´Ï´Ù.

 

The PosiTest AT-A can record fracture information for up to five layers.

For full details and examples see Visual Analysis and Recording of Test Results.

 

 

¡Ø DeFelsko °ø½Ä´ë¸®Á¡

 

NT_Defelsko_Certi.jpg