ŸÀÏ/ÄÜÅ©¸®Æ® ºÎÂø·ÂÃøÁ¤±â PosiTest ATA50T, C
* ¹Ì±¹ DeFelsko»çÀÇ 60³â µµ¸·ÃøÁ¤±â ³ëÇÏ¿ì
* µðÁöÅÐ ¹æ½ÄÀÇ ºÎÂø·Â ÃøÁ¤±â
* ±Ý¼Ó, ¸ñÀç, ÄÜÅ©¸®Æ® Ç¥¸éÀÇ ÄÚÆÃ, µµÀåÀÇ ºÎÂø·Â ½ÃÇè
* ¸ñÀç, ÄÜÅ©¸®Æ®À§ ÀÏ¹Ý ÄÚÆÃ(ATA50)
ŸÀϺÎÂø (ATA50T), ÄÜÅ©¸®Æ®À§ ¸ôÅ»(ATA50C) ºÎÂø·Â ½ÃÇè
* »ç¿ëÀÌ °£ÆíÇÏ°í Á¤È®ÇÑ ÃøÁ¤°ª Ç¥½Ã
* ¹«Àü¿ø, ¼ö¾Ð½ÄÆßÇÁ äÅÃÀ¸·Î ÇöÀå¿¡¼ ÃøÁ¤Æí¸®
* psi, MPa ´ÜÀ§ ¼±Åð¡´É
* Àü¿ë ¼ÒÇÁÆ®¿þ¾î·Î ÃøÁ¤°ª °ü¸® (´Ù¿î·Îµå)
* ASTM D4541, ISO 4624 µî ±× ¹ÛÀÇ ±âÁØÀ» Áؼö
* BS EN 12004-2, ASTM C1583 ±Ô°Ý
¡Ø Prime Distributor
DeFelsko ¿Í ´ºÅØ°è±â°¡ Æß¿þ¾î ÇѱÛÈ !
[¹Ì±¹»ê] 60³â ¿ª»çÀÇ DeFelsko»ç Á¦Ç°
* Àü±âÀûÀ¸·Î Á¦¾îµÇ´Â »õ·Î¿î hydraulic pump´Â »ç¿ëÀÚ°¡ ÁöÁ¤ÇÑ ºÎºÐ¿¡ ºÎµå·´°í Áö¼ÓÀûÀÎ ¾Ð·ÂÀ» ÀÚµ¿ÀûÀ¸·Î °¡¾Ð.
|
* 10, 14, 20 or 50 mm ÀÇ µ¹¸®µé·Î ÀÎÇØ Á¢Âø·ÂÀÇ Àü ºÎºÐ¿¡ °ÉÃļ ÃøÁ¤±âÀÇ ¼º´É°ú Á¤È®µµ°¡ ÃÖ´ëÈ.* »ç¿ëÀÚ ÃøÁ¤ ´ÜÀ§ ¼±Åð¡´É : psi (pounds per square inch), MPa (Megapascal),Nmm2 (Newtons per millimeter square) or Newton (force)* °Ë»çÀå¼ÒÀÇ È¯°æ¿¡ µû¶ó Àåºñ¸¦ °¡·Î ¶Ç´Â ¼¼·Î·Î µð½ºÇ÷¹ÀÌ ÇÏ°í ÀÛµ¿.* ¸ðµç ÀåºñÀÇ °¡¾ÐÀåÄ¡´Â NIST±Ô°Ý¿¡ ÁØÇÏ´Â ¡¾1% Á¤¹ÐµµÀÇ load cell·Î ±³Á¤ÇÏ°í ÀÚü ¼ºÀû¼¸¦ °ø±Þ.* ASTM D4541/D7234, ISO4624/16276-1, AS/NZS 1580.408.5 µîÀÇ ±Ô°Ý¿¡ ºÎÇÕÇÑ´Ù.
|
|
| |
¸Þ´º ¿É¼Ç°ú »óÈ£ ÀÛ¿ëÇϱâ À§ÇØ ÅÍÄ¡ ½ºÅ©¸°À» »ç¿ëÇÑ´Ù. ¹èÄ¡ Æǵ¶ »çÀ̸¦ À̵¿Çϰųª ¼öÆò Ž»öÇϱâ À§ÇØ ½º¿ÍÀÌÇÁ. ´ë¾ÈÀ¸·Î, Å°Æеå´Â Ž»ö ¹× ¼±ÅÃÀ» À§ÇØ »ç¿ëµÉ ¼öÀÖ´Ù. |
* »ç¿ëÀÚ´Â pull rate, pull limit, hold time Á¶Àý °¡´É * ¶³¾îÁü »óÅÂ¿Í Åë°ú/½ÇÆп¡ µû¶ó °á°ú¸¦ ±â·ÏÇÑ´Ù - cohesive, adhesive and glue failures * ¹«¼±À¸·Î ¿ì¸®ÀÇ ¹«·á ¾ÛÀ» »ç¿ëÇÏ¿© ½º¸¶Æ® ÀåÄ¡¿¡ ¿¬°á ¡Ý Ä«¸Þ¶ó ¶Ç´Â Å°º¸µå¸¦ »ç¿ëÇÏ¿© À̹ÌÁö ¹× ¸Þ¸ð Ãß°¡ ¡Ý »ç¿ëÀÚ Á¤ÀÇ, Àü¹® PDF º¸°í¼¸¦ ÀÛ¼º ¡Ý °øÀ¯, ¹é¾÷, µ¿±âÈ ¹× ÃøÁ¤ µ¥ÀÌÅ͸¦ º¸°í ¡Ý ÀÚµ¿ Æä¾î¸µ ºí·çÅõ½º (BLE) ¿¬°á * ³»ºÎ ¸Þ¸ð¸®´Â ÃÖ´ë Ç®-¿ÀÇÁ ¾Ð·Â, ÃÖ´ë 1,000 ¹èÄ¡¿¡ 100,000°³ ´ç±ä¿¡ ´ëÇÑ Ç®, ½ÃÇè ±â°£°ú µ¹¸® »çÀÌÁîÀÇ ¼Óµµ¸¦ ÀúÀåÇÒ ¼ö ÀÖ´Ù. * ¹«¼± WiFi ±â´É... PosiSoft.net·Î Åë½Å ¡Ý software updates ´Ù¿î·Îµå |
|
* PosiSoft USB Drive - ÀúÀåµÈ ÃøÁ¤ °ª°ú ±×·¡ÇÁ´Â º¸ÆíÀû ÀÎ PC / ¸Æ À¥ ºê¶ó¿ìÀú ¶Ç´Â ÆÄÀÏ Å½»ö±â¸¦ »ç¿ëÇÏ¿© USB¸¦ ÅëÇØ ¾×¼¼½º. º°µµÀÇ ¼ÒÇÁÆ®¿þ¾î°¡ ÇÊ¿äÇÏÁö ¾Ê½À´Ï´Ù. * PosiSoft µ¥½ºÅ©Åé ¼ÒÇÁÆ®¿þ¾î, PosiSoft.net ¹× PosiTector ÀÀ¿ë ÇÁ·Î±×·¥°ú ȣȯ |
User adjustable dolly size, pull rate, |
Batch summary provides an at-a-glance review of test results. |
View test parameters and reading results. Reading is recorded as pass or fail based on set test parameters. The pass/fail results can be revised. |
Notes can be added for each reading. |
Include a note for a batch (group) of readings. |
Record the nature of failure - cohesive, adhesive and glue failures. |
* PSI or MPaÀÇ µÎ°¡Áö ¾Ð·Â ´ÜÀ§·Î µð½ºÇ÷¹ÀÌ °¡´É
* 10, 14, 20 or 50 mm ÀÇ µ¹¸®µé·Î ÀÎÇØ Á¢Âø·ÂÀÇ Àü ºÎºÐ¿¡ °ÉÃļ ÃøÁ¤±âÀÇ ¼º´É°ú Á¤È®µµ°¡ ÃÖ´ëÈ µË´Ï´Ù.
Dolly Sizeº° ºÎÂø·Â °µµ
Dolly Size |
Adhesion Strength | |
10mm |
10000 psi |
70 MPa |
14mm |
6000 psi |
40 MPa |
20mm* |
3000 psi |
20 MPa |
50mm** |
500 psi |
3.5 MPa |
* supplied with PosiTest AT |
Dollies
pull-offÅ×½ºÆ®°¡ ¿Ï·áµÇ¸é, µ¹¸® ¹× ÄÚÆà ǥ¸éÀ» ºÐ¼®ÇÑ´Ù.
¶ÇÇÑ, pull-off ÈûÀ», ¸¹Àº ±¹°¡¿Í ±¹Á¦ Ç¥ÁØASTM D4541, ISO 4624¿¡¼´Â ¶³¾îÁü »óÅÂ(fracture)Ư¼º¿¡ ´ëÇÑ
±â·ÏÀ» ÇÊ¿ä·ÎÇÕ´Ï´Ù.
Á¢Âø½ÇÆд ÀϹÝÀûÀ¸·Î Á¢ÂøÁ¦°¡ ÀûÀýÇÏ°Ô È¥ÇÕ µÇÁö ¾ÊÀ» ¶§ ¹ß»ýÇϰųª, ÄÚÆà ¸é »óÅ°¡ ºÒ·®ÇÑ °æ¿ì¿¡
¹ß»ýÇÑ´Ù.
PosiTest AT-A ¸ðµ¨Àº °¢°¢ÀÇ pull-offÅ×½ºÆ®¸¦ À§ÇÑ ¶³¾îÁü(fracture) »óŸ¦¹®¼È ÇÒ ¼ö ÀÖ´Â ÀÎÅÍÆäÀ̽º¸¦
Á¦°øÇÕ´Ï´Ù. ¶³¾îÁü(fracture)»óÅ °á°ú´Â Å×½ºÆ® º¸°í¼¿¡ Æ÷ÇÔÇÒ ¼ö ÀÖ½À´Ï´Ù.
The PosiTest AT-A can record fracture information for up to five layers.
For full details and examples see Visual Analysis and Recording of Test Results.
¡Ø DeFelsko °ø½Ä´ë¸®Á¡