¹æ½ÄÀüÀ§ÃøÁ¤±â SD-21

* °¢Á¾ ö ±¸Á¶¹° ¹× ¹è°ü ºÎ½Ä»óÅ °Ë»ç
* ¼¼°è ÃÖÃÊÀÇ ÅëÇÕÇü : Àü¾Ð, Àü·ù, Á¢ÁöÀúÇ×, ÁÖÆļö µ¿½ÃÃøÁ¤ °¡´É
* ´ÜÀÏÀåºñ·Î ºñ¿ëÀý°¨ È¿°ú ¹× ÃøÁ¤, ÈÞ´ë ¿ëÀÌ
* ÇÁ¸°ÅÍ ³»ÀåÇü
* Á¢ÁöÀúÇ× ÃøÁ¤±â´É (Option)

±¹»ê Á¦Ç°

¹æ½ÄÀüÀ§ÃøÁ¤±â (SD-21)

Cathodic Protection Monitor (CP-monitor)

 

 Á¦Ç° Ư¡ 

- °¢Á¾ ö ±¸Á¶¹° ¹× ¹è°üÀÇ ºÎ½Ä»óÅ °Ë»ç

- ¼¼°èÃÖÃÊÀÇ ÅëÇÕÇüÀ¸·Î Àü¾Ð, Àü·ù, Á¢ÁöÀúÇ×, ÁÖÆļö¸¦ µ¿½ÃÃøÁ¤ °¡´É

- ´ÜÀÏÀåºñ·Î ºñ¿ëÀý°¨ È¿°ú ¹× ÃøÁ¤, ÈÞ´ë¿ëÀÌ

- ÇÁ¸°ÅÍ ³»ÀåÇü

- Á¢ÁöÀúÇ× ÃøÁ¤±â´É(Option_SD-21+ ¸ðµ¨)

 

- Test corrosion conditions of various constructions and steel pipes

- Joint development with KGS(Korea Gas Safety Corporation)

- Simultaneous measure of Voltage, electric current, ground resistance, frequency(the world's first)

- Easy measurement of alternative current interference and earth specific resistance

- Built-in printer type

- Earth Resistance Tester(Option)

 

 Á¦Ç° »ç¾ç

±¸ºÐ(Division)

¼¼ºÎ»çÇ×(Details)

ºñ°í(Reference)

 ÃøÁ¤¹üÀ§

 (Measuring range)

 ÀüÀ§

 (Voltage)

 DC 0 ~ ¡¾3,999 §Æ

 DC 0 ~ ¡¾399.9 V

 AC 0 ~ ¡¾599.9 V

 Æø³Ð°í ´Ù¾çÇÑ ÃøÁ¤¹üÀ§

 (Wide Various)

 Àü·ù

 (Current)

 0 ~ 1,999 §Ì

 ÀúÇ×

 (Resistance)

 0 ~ 1,999 §Ù

 0 ~ 19.99 §Û

 ÁÖÆļö

 (Frequency)

 0 ~ 9,999 §Ô

 10 ~ 50 §Õ

 Ç¥½Ã

 (LCD display)

 ÃÖ´ë, ÃÖ¼Ò, Æò±Õ°ª

 (Max, Min, Average)

 

 ³»ºÎÀúÇ×(ÀÔ·ÂÀÓÇÇ´ø½º)

 (Input impedance)

 100 §Û

 ÅäÁú¿¡µû¸¥ ¿Ö°î¾øÀ½

 (Accurate measure

 on any kinds of soil)

 ÇÁ¸°ÅÍ

 (Printer)

 ³»ÀåÇü

 (Internal)

 1, 5, 10 ȸ(Times)

 ¼±ÅûçÇ×

 (Optional Function)

 Á¢ÁöÀúÇ× ÃøÁ¤¸ðµå

 (Earth resistance

 Measurement mode)

 0 ~ 200 §Ù(0.1 §Ù)

 200 ~ 2,000 §Ù(1 §Ù)

 Á¦Ç°Å©±â(Dimension)

 195X40X85mm

 

 Á¦Ç° ¼Ò°³

SD-21Àº ÁöÇÏ¿¡ ¸Å¼³µÈ °¡½º°üÀÇ ºÎ½Ä ¹æÁö¸¦ À§ÇÏ¿© Èê·Á ÁÖ´Â [¹æ½Ä ÀüÀ§]¸¦ ÃøÁ¤Çϱâ À§ÇÑ Àåºñ·Î, ³»ºÎ ÀÔ·ÂÀúÇ×ÀÌ 100 §ÛÀ¸·Î

È­°­¾ÏÁöÇüÀÌ ¸¹Àº ±¹³» ½ÇÁ¤¿¡ ¸Â°Ô Àû¿ë µÇ¾î ÀÖ¾î ¾î¶°ÇÑ ÁöÇü¿¡¼­µµ ¿ÀÂ÷ ¾øÀÌ Á¤È®ÇÑ °ªÀ» ÃøÁ¤ÇÒ ¼ö ÀÖ½À´Ï´Ù

(ÀϹÝÀûÀΠŸ»ç Á¦Ç°Àº 1 §Û ¶Ç´Â 10 §ÛÀÇ ³»ºÎ ÀúÇ×À¸·Î ÀÌ·¯ÇÑ ³·Àº ³»ºÎÀúÇ×ÀÇ ±â±â·Î´Â ÅäÁöÀúÇ×ÀÌ ³ôÀº °÷Àº ¿ÀÂ÷°¡ Å­).

 

SD-21 is an equipment to measure [cathodic potential] spilling for corrosion prevention of gas pipe that is laid under the ground.

By 100 §Û input impedance, input resistance can be measured exactly without error in some topography because granite topographical

feature was applied according to a lot of domestic real conditions(Generally other equipments use 1 §Û or 10 §Û. Place that land

resistance is high is big error).

 