pH/DO/EC/ORP/TDS/¡É/Źµµ HI-9829

* 13°¡ÁöÀÇ ¼öÁúÇ׸ñ (6°¡Áö´Â ÃøÁ¤, 7°¡Áö´Â °è»ê) À» °ü¸®ÇÏ´Â ´ÙÇ׸ñ ÈÞ´ë±â±â
* ÃøÁ¤ÇÒ Ç׸ñ, ´ÜÀ§, ¾ð¾î¼±Åà ȯ°æ¼³Á¤
* ±×·¡ÇÁ¸¦ º¸¿©ÁÖ´Â 128 x 64 Çȼ¿ dot matrix ¾×Á¤
* °¢ Ç׸ñÀº º¸Á¤¸ðµå¿Í ÃøÁ¤µ¿¾È ¾×Á¤¿¡ °£Æí µµ¿ò¸» Á¦°ø
* T.I.S ÅÂ±× È®ÀÎ ½Ã½ºÅÛ (µ¥ÀÌÅÍ ¸ð´ÏÅ͸µ°ú ±â·Ï)
* À¯ÀÏÇÑ ID ¹øÈ£¸¦ °¡Áø iButton¨ÏÀº ¿©·¯ »ùÇøµ »çÀÌÆ®¿¡¼­ ¼³Ä¡°¡´É (·Î¡µÇ¸é ƯÁ¤Àå¼Ò Á¤º¸¸¦ ±â·ÏÇϴµ¥ »ç¿ë°¡´É)
* Á¾ÇÕÀûÀÎ GLP ±â´ÉÀ» Æ÷ÇÔÇϸç USB ¿¬°áÀ» ÅëÇØ µ¥ÀÌÅ͸¦ ´Ù¿î·Îµå
* IP67 ½ºÅÄ´Ùµå·Î Ãæ°Ý¿¡ °­ÇÏ°í ¹æ¼ö (¹° ¼Ó 1 m ¿¡¼­ 30ºÐ)
* ¹° ¼Ó¿¡¼­ °­ÇÑ ´Ù±â´É ¼¾¼­ ÇÁ·Îºê(IP68 standard)
* ¾ß¿Üº¸Á¤À» À§ÇØ ÇϳªÀÇ ¿ë¾×À¸·Î pH, Àüµµµµ, »ê¼Ò¸¦ ºü¸£°Ô º¸Á¤ °¡´É

¢º Á¦Ç° Ư¡

 * 12°¡Áö Ç׸ñÀ» ¾×Á¤¿¡ º¸¿©ÁÜ

 * ¹è°æÁ¶¸íÀ» °¡Áø ±×·¡ÇÈ LCD

 * ±â±â´Â IP67Ư¡ÀÌ ÀÖ°í ÇÁ·Îºê´Â IP68 ¹æ¼ö Ư¡ÀÌ ÀÖ´Ù.

 * GPS ±â´É žÀç·Î ¹«¼± µ¥ÀÌÅÍ ÀúÀå (À¯½Ç¹æÁö)

 


  HI-9829/4   = pH/DO/EC/ORP/TDS/ ¡É 

  HI-9829T /4 = pH/DO/EC/ORP/TDS/Źµµ/¡É 

                                                                                                                                                                                                                                                                                                                              


¢º Á¦Ç° »ç¾ç

¡¡

ÃøÁ¤¹üÀ§ (pH)

0.00 to 14.00 pH

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (pH)

0.01 pH

Á¤È®µµ (pH)

¡¾0.02 pH

ÃøÁ¤¹üÀ§ (mV of pH input)

¡¾600.0 mV

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (mV of pH input)

0.1 mV

Á¤È®µµ (mV of pH input)

¡¾0.5 mV

ÃøÁ¤¹üÀ§ (ORP)

¡¾2000.0 mV

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (ORP)

0.1 mV

Á¤È®µµ (ORP)

¡¾1.0 mV

ÃøÁ¤¹üÀ§ (Dissolved Oxygen)

0.0 to 500.0% / 0.00 to 50.00 mg/L

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Dissolved Oxygen)

0.1% / 0.01 mg/L

Á¤È®µµ (Dissolved Oxygen)

0.0 to 300.0%: ¡¾1.5% of reading or ¡¾1.0% whichever is greater; 300.0 to 500.0%: ¡¾3% of reading; 0.00 to 30.00 mg/L: ¡¾1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ¡¾3% of reading

ÃøÁ¤¹üÀ§ (Conductivity)

0.000 to 200.000 mS/cm (actual EC up to 400 mS/cm)

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Conductivity)

Manual: 1 ¥ìS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm Automatic: 1 ¥ìS/cm from 0 to 9999 ¥ìS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cm Automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm

Á¤È®µµ (Conductivity)

¡¾1% of reading or ¡¾1¥ìS/cm whichever is greater

Range (Resistivity)

0 to 999999 Ohm/cm; 0 to 1000.0 kOhm/cm; 0 to 1.0000 MOhm/cm

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Resistivity)

Dependent on resistivity reading

ÃøÁ¤¹üÀ§ (TDS)

0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (TDS)

Manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt) Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)

Á¤È®µµ (TDS)

¡¾1% of reading or ¡¾1mg/L

ÃøÁ¤¹üÀ§ (Salinity)

0.00 to 70.00 PSU (extended Practical Salinity Scale)

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Salinity)

0.01 PSU

Á¤È®µµ (Salinity)

¡¾2% of reading or 0.01 PSU whichever is greater

ÃøÁ¤¹üÀ§
(Seawater Specific Gravity)

0.0 to 50.0 st, s0, s15

ÃÖ¼ÒÃøÁ¤´ÜÀ§
(Seawater Specific Gravity)

0.1 st, s0, s15

Accuracy
(Seawater Specific Gravity)

¡¾1 st, s0, s15

ÃøÁ¤¹üÀ§ (Atm. Pressure)

450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Atm. Pressure)

0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Á¤È®µµ (Atm. Pressure)

¡¾2 mmHg within 15¡É from the temperature during calibration

Range (Temp)

-5.00 to 55.00¡É; 23.00 to 131.00¢µ; 268.15 to 328.15K

ÃÖ¼ÒÃøÁ¤´ÜÀ§ (Temp)

0.01¡É; 0.01¢µ; 0.01K

Á¤È®µµ (Temp)

¡¾0.15¡É; ¡¾0.27¢µ; ¡¾0.15K

ÃøÁ¤¹üÀ§(Nitrate)

0.02 to 200.0 ppm

ÃÖ¼ÒÃøÁ¤´ÜÀ§(Nitrate)

0.01 ppm to 1 ppm; 0.1ppm to 200ppm

Á¤È®µµ (Nitrate)

¡¾5% of reading or 2 ppm

ÃøÁ¤¹üÀ§(Turbidity)

0.0 to 50.0 FNU; 50 to 1000 FNU

ÃÖ¼ÒÃøÁ¤´ÜÀ§(Turbidity)

0.1 FNU from 0.0 to 50.0 FNU; 1 FNU from 50 to 1000 FNU

Á¤È®µµ(Turbidity)

¡¾0.3FNU or ¡¾2% of reading, whichever is greater

º¸Á¤ (pH)

Automatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer

º¸Á¤ (ORP)

Automatic at 1 custom point

º¸Á¤

Automatic 1 point with 6 memorized standards (84 ¥ìS/cm, 1413 ¥ìS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point

º¸Á¤

Automatic 1 or 2 points at 0, 100% or 1 custom point

º¸Á¤

Based on conductivity or salinity calibration

º¸Á¤

Automatic at 1 custom point

º¸Á¤

Automatic at 1 custom point

º¸Á¤

1 or 2 point 10 ppm and 100 ppm memorized standards 

º¸Á¤

Up to 3 points

¿Âµµº¸Á¤

Automatic from -5 to 55¡É

Logging ¸Þ¸ð¸®

Up to 46000 samples with 18 measurements each

Logging °£°Ý

1 second to 3 hours

Computer Interface

USB (with HI 929829 software)

¹æ¼öº¸È£

Meter IP67, Probe IP68

ȯ°æ

0 to 50¡É; RH 100%

Power Supply

(4) 1.5V alkaline C cells (´ë·«. ¹è°æÁ¶¸í ¾øÀÌ 150 ½Ã°£)/ (4) 1.2V rechargeable C cells (¹è°æÁ¶¸í ¾øÀÌ ¾à. 70 ½Ã°£)

±Ô°Ý

Meter: 221 x 115 x 55 mm; Probe: 270 x 46 mm DIA

¹«°Ô

Meter: 750g (26.5 oz.); Probe: 750g (26.5 oz.)

 


¢º Á¦Ç° ±¸¼º

- sensor hoder (HI 769828/4)

- PH/ORP sensor (HI-7609829-1)

- DO sensor (HI-7609829-2)

- EC/ Turbidity sensor (HI-7609829-4)

- HI 9828-25 ºü¸¥ º¸Á¤ Ç¥ÁØ¿ë¾×500 mL

- ÇÁ·Îºê º¸°üÅ°Æ®

- ÃæÀü°¡´ÉÇÑ C size Ni-MH ¹èÅ͸®

- ¾î´ðÅÍ & ÄÉÀ̺í

- car 12V accessory outlet adapter

- (5) È¦´õ¸¦ °¡Áø iButton¨Ï

- HI 7698291 USB interface cable

- HI 929829 W indows¢çcompatible software

- ÇѱÛ(¿µ¹®)¼³¸í¼­, ÇϵåÄÉÀ̽º°¡ ÇÔ²² °ø±ÞµË´Ï´Ù.