02
¢º Á¦Ç° Ư¡
edge´Â ¾ã°í °¡º¿ì¸ç, ³ÐÀº ȸé°ú ÅÍÄ¡½Ä Å°Æеå·Î µðÀÚÀÎ µÇ¾ú½À´Ï´Ù.
edge´Â Æ¯ÈµÈ Àü±ØÀ» »ç¿ëÇÏ¿© Àüµµµµ(EC) ÃøÁ¤ÇÕ´Ï´Ù.
ÃøÁ¤, º¸Á¤, ·Î¡°ú ÄÄÇ»ÅÍ È¤Àº USB µå¶óÀ̺ê·Î Àü¼ÛÀÌ ½±½À´Ï´Ù.
HI 763100 Àü±Ø°ú ÇÔ²² Á¦°øµË´Ï´Ù.
¢º Á¦Ç° »ç¾ç |
|
EC Range |
0.00 to 29.99 ¥ìS/cm, 30.0 to 299.9 ¥ìS/cm, 300 to 2999 ¥ìS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)** |
EC Resolution |
0.01 ¥ìS/cm, 0.1 ¥ìS/cm, 1 ¥ìS/cm, ,0.01 mS/cm, 0.1 mS/cm |
EC Accuracy (@25¨¬C/77¨¬F) | ¡¾1% of reading (¡¾0.05 ¥ìS/cm or 1 digit, whichever is greater) |
EC Calibration | 1 point offset calibration (0.00 ¥ìS/cm in air), 1 point slope calibration in EC standard 84 ¥ìS/cm, 1413 ¥ìS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
TDS Specifications | ¡¡ |
TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)** |
TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
TDS Accuracy (@25¨¬C/77¨¬F) | ¡¾1% of reading (¡¾0.03 ppm or 1 digit, whichever is greater) |
TDS Calibration | through EC calibration |
TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
Salinity
Specifications |
|
Salinity Range | 0.0 to 400.0% NaCl, 2.00 to 42.00 PSU, 0.0 to 80.0 g/L* |
Salinity Resolution | 0.1% NaCl, 0.01 PSU, 0.01 g/L |
Salinity Accuracy (@25¨¬C/77¨¬F) | ¡¾1% of reading |
Temperature..Specifications | |
Temperature Range | -20.0 to 120.0 ¨¬C, -4.0 to 248.0 ¡ÆF |
Temperature Resolution | 0.1 ¡ÆC, 0.1 ¡ÆF |
Temperature Accuracy | ¡¾0.5 ¡ÆC, ¡¾0.9 ¡ÆF |
¡ÆC/¡ÆF | Yes |
Additional
Specifications |
|
EC/TDS/Salinity Temperature Compensation | Automatic -5 to 100¨¬ C (23 to 212¨¬ F) NoTC - can be selected to measure absolute conductivity. |
Conductivity Temperature Coefficient | 0.00 to 6.00% / ¨¬C |
GLP | Yes |
Logging | up to 1000 (400 for basic mode) records organized in: manual log-on-demand (max. 200 logs), manual log-on-stability* (max. 200 logs), interval logging¢Ó (max. 600 samples; 100 lots) |
Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
Environment | 0 to 50¡ÆC (32 to 122¡ÆF), RH max 95% non-condensing |
Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Dimensions | 202 x 140 x 12.7mm (8¡± x 5.5¡± x 0.5¡±) |
Weight | 250 g (8.82 oz) |
Ordering Information | edge¢çEC HI2003 includes: HI763100 Conductivity probe, 4 sachets of 1413 ¥ìS/cm conductivity standard, 2 sachets of 5000 ¥ìS/cm conductivity standard, 2 sachets of 12880 ¥ìS/cm conductivity standard, 2 sachets general purpose rinse solution, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificate and instruction manual. |
Warranty | 2 years (probe 6 months) |
Notes | * Not available in basic mode |
** with temperature compensation function disabled |