¡Ú COD/ÃÑÁú¼Ò/ÃÑÀÎ/pH/¾Ï¸ð´Ï¾Æ HI83314
CODÃøÁ¤±â, ÃÑÀÎ, ÃÑÁú¼Ò, COD, HI83314
¢º Á¦Ç° Ư¡
* ¿À, Æó¼öºÐ¼®½Ã½ºÅÛ
* 10°³ Ç׸ñÀÇ ÀÌ¿Â ºÐ¼®¿¡ ´ëÇÑ 20°³ÀÇ ÃøÁ¤¹æ¹ý (´Ù¾çÇÏ°Ô »ç¿ëÇϱ⿡ ÀûÀýÇÔ)
* ÃÖ´ë 1000°³ÀÇ µ¥ÀÌÅÍ ÀúÀå & PC ȣȯ
* 128 x 62 Çȼ¿ ±×·¡ÇÈ LCD ȸé
* ÀÌ¿Â ÃøÁ¤¿¡ ´Ù¸¥ ³»ÀåÇü ŸÀ̸Ó
* Èí±¤µµ ÃøÁ¤¸ðµå (Absorbance Measurement Mode)
* HI 83314´Â EPA 410.4¿Í ISO 15705:2002 Ç¥ÁØ¿¡ µû¶ó COD¸¦ ºÐ¼®Çϱâ À§ÇØ µðÀÚÀεǾú½À´Ï´Ù.
* Á¤È®ÇÑ °á°ú¸¦ º¸ÀåÇÏ¸é¼ µ¥ÀÌÅ͸¦ ±â·ÏÇϱâ À§ÇÑ ÀÌ»óÀûÀÎ µµ±¸ÀÔ´Ï´Ù.
* CODÀÇ Áß¿äÇÑ Ç׸ñ ¿Ü¿¡µµ,ÃÑÁú¼Ò,ÃÑÀÎ,PH,¾Ï¸ð´Ï¾ÆÀ» ÃøÁ¤ÇÕ´Ï´Ù.
* ±â°è´Â RS232 ½Ã¸®¾ó Æ÷Æ®¸¦ ÅëÇØ PC¿Í ¿¬°á µÉ ¼ö ÀÖ°í ÀúÀåµÈ ÃøÁ¤°ªÀº HI 92000¼ÒÇÁÆ®¿þ¾î ÇÁ·Î±×·¥À» »ç¿ëÇÏ¿©
PC·Î ´Ù¿î·ÎµåÇÒ ¼ö ÀÖ½À´Ï´Ù.
* HI 83314´Â ÇϳªÀÇ ±â°è·Î ¿Ïº®ÇÏ°Ô Æó¼öºÐ¼®À» ÇÕ´Ï´Ù.
¢º Á¦Ç° »ç¾ç
pH |
Range |
Photometer: 6.5 to 8.5 pH |
pH electrode: -2.00 to 16.00 pH | ||
Resolution |
Photometer: 0.1 pH | |
pH electrode: 0.01 pH | ||
Accuracy |
Photometer: ¡¾0.1 pH | |
pH electrode: ¡¾0.01 pH | ||
Calibration |
Automatic one or two point calibration with one set of | |
standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01) | ||
Temperature |
Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based | |
Compensation |
on the pH electrode used | |
CAL Check |
clean electrode and check buffer/check probe displayed during calibration | |
( electrode diagnostics) | ||
Method |
Photometer: phenol red | |
pH-mV Range |
¡¾1000 mV | |
pH-mV Resolution |
0.1 mV | |
pH-mV Accuracy |
¡¾0.2 mV | |
Absorbance |
Range |
0.000 to 4.000 Abs |
Resolution |
0.001 Abs | |
Accuracy |
¡¾0.003Abs @ 1.000 Abs | |
Ammonia |
Range |
Low Range: 0.00 to 3.00 mg/L |
Low Range (16 mm vial): 0.00 to 3.00 mg/L | ||
Medium Range: 0.00 to 10.00 mg/L | ||
High Range: 0.0 to 100.0 mg/L | ||
High Range (16 mm vial): 0.0 to 100.0 mg/L | ||
(all as NH3-N) | ||
Resolution |
0.01 mg/L; 0.1 mg/L | |
Accuracy |
Low Range: ¡¾0.04 mg/L ¡¾4% of reading | |
Low Range (16 mm vial): ¡¾0.10 mg/L or ¡¾5% of reading | ||
Medium Range: ¡¾0.05 mg/L ¡¾5% of reading | ||
High range: ¡¾0.5 mg/L ¡¾5% of reading | ||
High range (16 mm vial): ¡¾1 mg/L or ¡¾5% of reading | ||
Method |
Adaptation of the ASTM Manual of Water and Environmental Technology, | |
D1426-92, Nessler method | ||
Chemical Oxygen |
Range |
Low Range: 0 to 150 mg/L |
Demand |
Medium Range: 0 to 1500 mg/L | |
¡¡ |
High Range:0 to 15000 mg/L | |
¡¡ |
Resolution |
Low and Medium Range: 1 mg/L |
¡¡ |
High Range: 10 mg/L | |
¡¡ |
Accuracy |
Low Range: ¡¾5 mg/L ¡¾5% of reading |
¡¡ |
Medium Range: ¡¾15 mg/L ¡¾4% of reading | |
¡¡ |
High Range: ¡¾150 mg/L ¡¾3% of reading | |
¡¡ |
Method |
Adaptation of the USEPA 410.4 |
¡¡ |
ISO dichromate methods | |
¡¡ |
Mercury-free dichromate green method (LR & MR); | |
¡¡ |
dichromate method (HR) | |
Chlorine |
Range |
0.00 to 5.00 mg/L (as Cl2) |
Resolution |
0.01 mg/L | |
Accuracy |
¡¾0.03 mg/L ¡¾3% of reading | |
Method |
Adaptation of the EPA 330.5 DPD method | |
Nitrate |
Range |
16 mm vial: 0.0 to 30.0 mg/L (as NO3_-N) |
Resolution |
0.1 mg/L | |
Accuracy |
16 mm vial: ¡¾1.0 mg/L or ¡¾3% of reading | |
Method |
Adaptation of the cadmium reduction method | |
Nitrite |
Range |
Freshwater |
Low Range: 0 to 600 ¥ìg/L (as NO2_-N) | ||
High Range: 0 to 150 mg/L (as NO2_) | ||
Resolution |
Freshwater: 1 ¥ìg/L; 1 mg/L | |
Accuracy |
Freshwater | |
Low Range: ¡¾20 ¥ìg/L ¡¾4% of reading | ||
High Range: ¡¾4 mg/L ¡¾4% of reading | ||
Method |
Adaptation of the EPA Diazotization method 354.1 | |
Nitrogen, Total |
Range |
Low Range: 0.0 to 25.0 mg/L (as NO3_-N) |
High Range: 0 to 150 mg/L (as N)) | ||
Resolution |
0.1 mg/L; 1 mg/L | |
Accuracy |
Low Range: ¡¾1.0 mg/L or ¡¾5% of reading | |
High Range: ¡¾3 mg/L or ¡¾4% of reading | ||
Method |
Chromotropic acid method | |
Phosphorous, |
Range |
0.00 to 1.60 mg/L (as P) |
Acid Hydrolyzable |
Resolution |
0.01 mg/L |
¡¡ |
Accuracy |
¡¾0.05 mg/L or ¡¾5% of reading |
¡¡ |
Method |
Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method |
Phosphorous, Reactive |
Range |
Low Range: 0.00 to 1.60 mg/L (as P) |
High Range: 0.0 to 32.6 mg/L (as P) | ||
Resolution |
0.01 mg/L; 0.1 mg/L | |
Accuracy |
Low Range: ¡¾0.05 mg/L or ¡¾4% of reading | |
High Range: ¡¾0.5 mg/L or ¡¾4% of reading | ||
Method |
Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th edition and EPA method 365.2 (low range) | |
Low Range: ascorbic acid method | ||
High Range: vanadomolybdophosphoric acid method | ||
Phosphorous, Total |
Range |
Low Range: 0.00 to 1.15 mg/L (as P) |
High Range: 0.0 to 32.6 mg/L (as P) | ||
Resolution |
Low Range: 0.01 mg/L; 0.1 mg/L | |
Accuracy |
Low Range: ¡¾0.05 mg/L or ¡¾6% of reading | |
High Range: ¡¾0.5 mg/L or ¡¾5% of reading | ||
Method |
Adaptation of Standard Methods for the Examination of Water and | |
Wastewater, 20th edition and EPA method 365.2 (low range) | ||
Low Range: ascorbic acid method | ||
High Range: vanadomolybdophosphoric acid method | ||
±âŸ »ç¾ç |
Input Channels |
1pH electrode input and 5 photometer wavelengths |
pH Electrode |
digital pH electrode (not included) | |
Logging Type |
log on demand with user name and sample ID optional input | |
Logging Memory |
1000 readings | |
Connectivity |
USB-A host for flash drive; micro-USB-B for power and computer connectivity | |
GLP |
calibration data for connected pH electrode | |
Display |
128 x 64 pixel LCD with backlight | |
Battery Type / Life |
3.7 VDC Li-polymer rechargeable battery / 500 photometric measurements or 50 hours of continuous pH measurement | |
Power Supply |
5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) | |
Environment |
0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing | |
Dimensions |
206 x 177 x 97 mm (8.1 x 7.0 x 3.8") | |
Weight |
1.0 kg (2.2 lbs.) | |
Photometer / |
5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band i nterference filters | |
Colorimeter Light Source | ||
Photometer / |
silicon photodetector | |
Colorimeter Light Detector | ||
Bandpass Filter |
8 nm | |
Bandwidth | ||
Bandpass Filter Wavelength Accuracy |
¡¾1 nm | |
Cuvette Type |
round, 24.6 mm | |
Number of Methods |
128 max | |
¢º ÁÖ¹® Á¤º¸ | ||
HI 83314 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual |
¢º ÃøÁ¤½Ã¾à º°¸Å
*½Ã¾à COD / Low (HI-93754A)-25ȸºÐ(0 ~ 150§·/§¤)
*½Ã¾à COD / Med (HI-93754B)-25ȸºÐ(0 ~ 1,500§·/§¤)
*½Ã¾à COD / Hi (HI-93754C)-25ȸºÐ(0 ~ 15,000§·/§¤)
*½Ã¾à ÃÑÁú¼Ò/ LR (HI-93767A)-50ȸºÐ(0.0 ~ 25§·/§¤)
*½Ã¾à ÃÑÁú¼Ò/ HR (HI-93767B)-50ȸºÐ(0 ~ 150§·/§¤)
*½Ã¾à ÃÑÀÎ/ LR (HI-93758C-50) -50ȸºÐ(0.00 ~ 1.15§·/§¤)
*½Ã¾à ÃÑÀÎ/ HR (HI-93763B-50) -50ȸºÐ(0.0 ~ 32.6§·/§¤)